V4 40 Lpm sectional spool valve A low profile mobile sectional spool valve which can be lever, solenoid or cable operated. It is suitable for open or closed centre circuits and there are spool options for 2, 3, & 4 position valves, all with good metering characteristics. Fine metering spools are also available and a direct acting main relief valve can be incorporated into the inlet cover. Extensive range of inter-section and ancillary valves are available.
The V4 valve range supercedes the V1-40 entirely and components are not interchangeable.
To view the complete V4 catalogue Click here![]()
(Please allow a few moments for the catalogue to load.)
Alternatively to view the individual data sheets click on the links below.
Spool section and |
Technical description and options for the main spool section and the inlet and outlet covers. |
Datasheet |
| Service line relief valve | Limits the pressure in individual service lines and provides anticavitation protection in circuits with overrun situations. Maintains oil in the actuators. | Datasheet |
| Cross line relief valve | Relieves pressure from one service line to the other using only one relief valve cartridge. | Datasheet |
| Pilot check valve | Used to lock one or both service ports to ensure that there is zero movement of the actuator whilst its control valve is in neutral. | Datasheet |
| Flow control sections | Pressure compensated meter-in type flow control for a V4 valve assembly. Regulated flow is supplied via a pressure gallery to downstream sections while upstream is unaffected. | Datasheet |
| Flow divider sections | Allows two hydraulic circuits to be built into one valve assembly. The supply is connected directly to the section. | Datasheet |
| Series connector | For fitting between two valve sections to connect in series the actuators they control. May be used to synchronize two hydraulic motors where return oil from one is fed into the inlet of the second. | Datasheet |
| Mid inlet section | Used to feed a second hydraulic supply into a valve chest so that two separate control assemblies can be build into one valve chest. | Datasheet |
| Solenoid Unloader Section | Requires a constant voltage supply to enable operation of all valve functions. Dumps to tank in the un-energised state. | Datasheet |
Rotary Lever | Designed especially for winch applications. Provides fine control of spool position with friction hold. Fully marinised. | Datasheet |
| Dual Axis Lever | Full control of two spools from one lever. Two options available. |
Datasheet |